Energy Saving Basement Finishing Ideas Alaska

This was designed to prevent condensation from forming on the top half of the foundation wall that was exposed above ground level...

Local & National Companies

K R Kitchens and Baths
603-491-7570
272 River Road
Epsom, AK
Solid Design Fabricators Inc.
850-484-8401
920 Industrial Court
Pensacola, AK
vortexremodelilngLTD
330 662 4035
1114 n court st
medina, AK
Johnson Todd M Construction Co
(517) 552-7264
Howell, MI
J.R. Anderson Construction
(586) 948-4000
46412 Community Center Dr
Chesterfield, MI
Ross Construction Llc
(307) 778-7164
6517 Woods Rd
Cheyenne, WY
Basement Builders
(651) 407-0707
Saint Paul, MN
Family Basement Wall Repair Inc
(517) 546-4148
3674 E Coon Lake Rd
Brighton, MI
Richard L Higgins Inc
(316) 838-3646
3609 N Meridian Ave
Wichita, KS
Itsell Construction Co
(517) 548-1384
1219 N Michigan Ave
Howell, MI


Energy Saving Basement Finishing Ideas

provided by: 
Written by Dave Murray - Barricade

In Ontario, all new homes built after 1975 had to have basement foundation wall insulation with an R12 rating just two feet down from the sill plate. This was designed to prevent condensation from forming on the top half of the foundation wall that was exposed above ground level. This code provision is a standard component of all Canadian and United States building codes today. For older homes built before 1975, there was typically no basement insulation.

Recently, the Ontario building code, effective by December 2008, was amended to mandate the installation of full floor-to-ceiling basement wall R-12 insulation. The reason for this was recognition that full basement wall insulation provided better protection against moisture forming on the foundation wall surface, due to high interior relative humidity. Reducing moisture in the basement will help eliminate potential health problems with mold and fungus growth. The added insulation will also help achieve significant energy cost savings.

For an existing home, if a homeowner is looking at a basement renovation, it makes sense and cents to do it right with full R12 insulation on the foundation walls and R 3 on the basement floors.

The only basement finishing system that integrates basement wall insulation with basement floor insulation is the Barricade modular panel system by Ovrx. Barricade integrates an engineered wood core with closed-cell polystyrene insulation that provides the warmth and comfort of real insulation but also acts as a code-approved vapor barrier for the walls and floors.

What kind of savings can a homeowner expect when they finish their basement with the Barricade system?

Using REM Design energy analysis software, the energy savings were calculated on a typical Toronto home with the Barricade system. Potential savings of $90 per year, or up to 10% of the total heating cost, with partial foundation wall insulation are possible, and $379 per year, or up to 30% of the total annual heating cost, if there was no basement wall insulation. *

Clearly homeowners need to incorporate this type of wall and floor insulation into their basement design. When the basement renovations are complete, the end result will be a warm, dry comfortable, safe and energy-saving living space for the family.

(A) R-12 Batt, 2 ft draped (insulated band joist) and no slab insulation1) Foundations energy consumption: 24.5 MMBtu/Yr (Cost of $232/Yr)2) Slab energy consumption: 6.8 MMBtu/yr (Cost of $65/Yr)

(B) R-12 STYROFOAM full height on interior basement walls and slab insulation for R 2.5 STYROFOAM1) Foundation energy consumption: 15.5 MMBtu/Yr (Cost of $147/Yr)2) Slab energy consumption: 6.3 MMBtu/Yr (Cost of $60/yr)

(C) No basement wall insulation and no slab insulation1) Foundations energy consumption: 55.0 MMBtu/Yr (Cost of $521/Yr)2) Slab energy consumption: 6.8 MMBtu/yr (Cost of $65/Yr)

Potential Savings

Partial basement wall insulation and no slab insulation: A-B ($297 - $207) = $90No basement wall insulation and no slab insulation: C-B ($586 - $207) = $379

By Dave Murray


article at HomeRenovationGuide.com

Featured Local Company

vortexremodelilngLTD

330 662 4035
1114 n court st
medina, AK

Related Local Events
Anchorage Home Expo
Dates: 9/12/2008 - 9/14/2008
Location: George M. Sullivan Arena
Anchorage AK
View Details

Anchorage HomEXPO
Dates: 9/12/2008 - 9/14/2008
Location: GEORGE M. SULLIVAN ARENA
Anchorage AK
View Details
Rate Article
     
Articles Insider

Rss   Delicious   Digg   Add To My Yahoo   Add To My Google   Bookmark   Search Plugin

Topics:
Advertising Educational Content Home Appliances Real Estate Resources
Business Services Entertainment Home Electronics Software
Career Family Home Services Technology
Cars Fashion Internet Telecommunications
Chamber of Commerce Financial Services Legal Trade Shows
Computer Hardware Franchise Miscellaneous Travel
Construction Health Nightlife Weddings
Education Holidays Online Database World History