Energy Saving Basement Finishing Ideas Nevada

This was designed to prevent condensation from forming on the top half of the foundation wall that was exposed above ground level...

National Companies

Family Basement Wall Repair Inc
(517) 546-4148
3674 E Coon Lake Rd
Brighton, MI
Dolphin Remodeling
(303) 799-8870
1565 Meyerwood Cir
Littleton, CO
Blass Construction Co
(785) 738-2116
321 S Poplar St
Beloit, KS
J & J Builders
(402) 933-7750
11661 Hartman Ave
Omaha, NE
Metro Basements & Waterproofing
(817) 596-4857
505 Valley Trail Dr
Weatherford, TX
Hard Rock Interiors
(970) 568-4414
Wellington, CO
Clearview of Harrisburg Llc
(717) 671-1700
3990 Paxton St
Harrisburg, PA
Leaky Solutions Waterproofing
(620) 728-1606
Hutchinson, KS
Greg Evans Carpentry
(319) 337-3827
1806 Flatiron Ave
Iowa City, IA
Ajs Builders Inc
(630) 892-1392
Aurora, IL


Energy Saving Basement Finishing Ideas

provided by: 
Written by Dave Murray - Barricade

In Ontario, all new homes built after 1975 had to have basement foundation wall insulation with an R12 rating just two feet down from the sill plate. This was designed to prevent condensation from forming on the top half of the foundation wall that was exposed above ground level. This code provision is a standard component of all Canadian and United States building codes today. For older homes built before 1975, there was typically no basement insulation.

Recently, the Ontario building code, effective by December 2008, was amended to mandate the installation of full floor-to-ceiling basement wall R-12 insulation. The reason for this was recognition that full basement wall insulation provided better protection against moisture forming on the foundation wall surface, due to high interior relative humidity. Reducing moisture in the basement will help eliminate potential health problems with mold and fungus growth. The added insulation will also help achieve significant energy cost savings.

For an existing home, if a homeowner is looking at a basement renovation, it makes sense and cents to do it right with full R12 insulation on the foundation walls and R 3 on the basement floors.

The only basement finishing system that integrates basement wall insulation with basement floor insulation is the Barricade modular panel system by Ovrx. Barricade integrates an engineered wood core with closed-cell polystyrene insulation that provides the warmth and comfort of real insulation but also acts as a code-approved vapor barrier for the walls and floors.

What kind of savings can a homeowner expect when they finish their basement with the Barricade system?

Using REM Design energy analysis software, the energy savings were calculated on a typical Toronto home with the Barricade system. Potential savings of $90 per year, or up to 10% of the total heating cost, with partial foundation wall insulation are possible, and $379 per year, or up to 30% of the total annual heating cost, if there was no basement wall insulation. *

Clearly homeowners need to incorporate this type of wall and floor insulation into their basement design. When the basement renovations are complete, the end result will be a warm, dry comfortable, safe and energy-saving living space for the family.

(A) R-12 Batt, 2 ft draped (insulated band joist) and no slab insulation1) Foundations energy consumption: 24.5 MMBtu/Yr (Cost of $232/Yr)2) Slab energy consumption: 6.8 MMBtu/yr (Cost of $65/Yr)

(B) R-12 STYROFOAM full height on interior basement walls and slab insulation for R 2.5 STYROFOAM1) Foundation energy consumption: 15.5 MMBtu/Yr (Cost of $147/Yr)2) Slab energy consumption: 6.3 MMBtu/Yr (Cost of $60/yr)

(C) No basement wall insulation and no slab insulation1) Foundations energy consumption: 55.0 MMBtu/Yr (Cost of $521/Yr)2) Slab energy consumption: 6.8 MMBtu/yr (Cost of $65/Yr)

Potential Savings

Partial basement wall insulation and no slab insulation: A-B ($297 - $207) = $90No basement wall insulation and no slab insulation: C-B ($586 - $207) = $379

By Dave Murray


article at HomeRenovationGuide.com

Featured National Company

Deco Construction

916-496-1666
Folsom
Folsom, CA
www.decoconstruction.net

Related Local Events
Self-Storage 2008 Fall Conference and Tradeshow
Dates: 9/3/2008 - 9/5/2008
Location: Ceasers Palace
Las Vegas NV
View Details

Home Improvement and Backyard Living Expo
Dates: 9/5/2008 - 9/7/2008
Location: South Point events Center
Las Vegas NV
View Details

Home Improvement and Backyard Living Expo
Dates: 9/5/2008 - 9/7/2008
Location: South Point Events Center
Las Vegas NV
View Details

HomeWorld-Home Improvement and Home Living Expo
Dates: 9/5/2008 - 9/7/2008
Location: South Point Hotel and Casino
Las Vegas NV
View Details

Log Home and Timber Frame Expo
Dates: 9/12/2008 - 9/14/2008
Location: TBD
Las Vegas NV
View Details
Rate Article
     
Articles Insider

Rss   Delicious   Digg   Add To My Yahoo   Add To My Google   Bookmark   Search Plugin

Topics:
Advertising Educational Content Home Appliances Real Estate Resources
Business Services Entertainment Home Electronics Software
Career Family Home Services Technology
Cars Fashion Internet Telecommunications
Chamber of Commerce Financial Services Legal Trade Shows
Computer Hardware Franchise Miscellaneous Travel
Construction Health Nightlife Weddings
Education Holidays Online Database World History