Exposed Masonry Walls Cicero IL

A partially completed masonry wall in Cicero was left without any covering on the top over the winter. Consequently, the top of the wall was exposed to snow and rain for several months.

Local Companies

E & L Drywall Finishers N Painting Services Inc.
(773) 235-7113
1100 N Ridgeway Ave
Chicago, IL
Alande Drywall
(312) 829-0434
1009 S Oakley Bl
Chicago, IL
Atop Construction
(773) 884-6100
5525 S Kedvale Av
Chicago, IL
Diaz Drywall & Taping
(773) 531-7451
6637 S California Av
Chicago, IL
McNulty Brothers Co.
(312) 850-6400
2009 S Lumber St
Chicago, IL
Altamirano Drywall
(773) 208-9404
3448 N Kilbourn Ave
Chicago, IL
Remodeling Masters Inc.
(773) 617-2329
4183 N Elston Ave
Chicago, IL
Benegas Drywall Inc.
(773) 463-8400
3741 N Christiana Ave
Chicago, IL
Janecyk Construction
(312) 781-9815
188 W Randolph St
Chicago, IL
Rudek Construction Services Incorporated
(773) 764-8685
1454 W Thome Ave
Chicago, IL

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: March 1, 2003

A partially completed masonry wall was left without any covering on the top over the winter. Consequently, the top of the wall was exposed to snow and rain for several months.

What problems can this situation create?

Exposing the top of a brick wall to rain and melting snow allows water to collect in the cores of the brick units, which can cause the upper portion of the wall to become saturated. This exposure is typically much more severe than rainwater penetration through the face of the completed wall.

Saturated masonry can undergo several freeze/thaw cycles during the winter in a northern climate. This action can contribute to premature deterioration of the masonry, especially if the cores of the brick units are filled with water when the wall freezes.

Snow and ice are typically more damaging to masonry construction than rainwater. A portion of the snow or ice melts during the day and refreezes at night, which makes the walls undergo daily freeze/thaw cycles. Repeated wetting of the walls also increases efflorescence concerns.

In regard to the specific wall in the question, deterioration that occurs as a result of multiple freeze/thaw cycles during the limited time frame in which the wall was exposed to moisture during cold temperatures is likely to occur only in the upper portions. Any efflorescence that occurred can be cleaned off the wall.

This limited exposure to severe weathering ...

Click here to read full article from Masonry Construction

Featured Local Company

E & L Drywall Finishers N Painting Services Inc.

(773) 235-7113
1100 N Ridgeway Ave
Chicago, IL

Related Articles
- Insulated Cavity Walls Cicero IL
Depending on the project's construction sequencing, there may be an advantage to using one approach over the other. Walls can be built to work properly either way, but it's more difficult to create a free-draining cavity when both wythes are built at the same time.
- Analyzing Wet Walls Cicero IL
- Bond Beams Cicero IL
- Brick Basement Walls Cicero IL
- Building in the Rain Cicero IL
- Wall Bracing Products Cicero IL
- Building with masonry can prevent mold Cicero IL
- Designing and Building Pilasters Cicero IL
- Lintel Design and Detailing Cicero IL
- Preventing Moisture Penetration Cicero IL
Related Articles
- Insulated Cavity Walls Cicero IL
Depending on the project's construction sequencing, there may be an advantage to using one approach over the other. Walls can be built to work properly either way, but it's more difficult to create a free-draining cavity when both wythes are built at the same time.
- Analyzing Wet Walls Cicero IL
- Bond Beams Cicero IL
- Brick Basement Walls Cicero IL
- Building in the Rain Cicero IL
- Wall Bracing Products Cicero IL
- Building with masonry can prevent mold Cicero IL
- Designing and Building Pilasters Cicero IL
- Lintel Design and Detailing Cicero IL
- Preventing Moisture Penetration Cicero IL
Related Local Events
PLASTICS USA / PLASTEC Midwest - Plastics Industry Trade Fair
Dates: 9/28/2010 - 9/30/2010
Location: Donald E. Stephens Convention Center
Rosemont, IL
View Details

ISSA/INTERCLEAN NORTH AMERICA 2009
Dates: 10/6/2009 - 10/9/2009
Location: McCormick Place
Chicago, IL
View Details

Rss   Delicious   Digg   Add To My Yahoo   Add To My Google   Bookmark   Search Plugin

Topics:
Advertising Family Home Services Real Estate Resources
Business Services Fashion Industrial Goods & Services Retail & Consumer Services
Career Financial Services Insurance Software
Cars Food & Beverage Internet Technology
Computer Hardware Franchise Legal Telecommunications
Construction Health Miscellaneous Trade Shows
Education Holidays Nightlife Travel
Entertainment Home Appliances Online Database Weddings
Environmental Home Electronics Pets World History