Proper Cleat Installation Oshkosh WI

Installing metal roofing is a craft. It requires more skill and a greater knowledge than installing other roofing materials.An important consideration for properly installing standing seam roofing is proper cleat installation.

Local Companies

Ideal Roofing & Gutters,LLC
920-923-2251
310 Tompkins St.
Fond du Lac, WI
Property Restoration Services, LLC
920-915-6993
411 E Crossing Meadows Ln
Appleton, WI
Fond Du Lac Distributors Inc
(920) 921-1600
1160 W Scott St
Fond Du Lac, WI
R & R Cedar Co
(715) 799-3805
N2630 W Branch Rd
Keshena, WI
Kerscher Building & Heating
(920) 682-7826
1125 S Rapids Rd
Manitowoc, WI
Manion's Components
(715) 395-7890
1001 Garfield
Superior, WI
Mule-Hide Products Co Inc
(608) 365-3111
1195 Prince Hall Dr
Beloit, WI
Leafguard of Wisconsin Inc
(262) 574-1818
N12W24362 Bluemound Rd
Waukesha, WI
Infinity Capital
(608) 361-6680
655 3rd St
Beloit, WI
United Products Corp
(715) 831-0855
2520 Davey St
Eau Claire, WI

Provided by:

From ESE Machines



Installing metal roofing is a craft. It requires more skill and a greater knowledge than installing other roofing materials.

An important consideration for properly installing standing seam roofing is proper cleat installation. ESE Machines (www.esemachines.com) offers the following guidelines on its website.



How many cleats?

The rule of thumb is one (1) cleat should be responsible for every 1-1/2 square feet of roof area.

Therefore, the formula to get the total number of cleats required: Divide square footage of the roof area by 1.5 = number of cleats for that roof.



Cleat spacing considerations

Divide 216 by the width of your panel to determine cleat spacing because 216 is the number of square inches per 1-1/2 square feet. As an example, for a panel width of 18 inches, divide 216 by 18 = cleat spacing every 12 in.

Simply put:

— a 12-inch wide panel should have cleats every 18 inches

— an 18-inch wide panel should have cleats every 12 inches

— a 24-inch wide panel should have cleats every 9 inches



Perimeter areas are more critical!

The amount of fasteners used at the ridge, eaves and rakes should be doubled from the formula above. This means if you have a cleat every 12 inches up the roof then you should have two within 6 inches of each other at the eave, the ridge and every 6 inches along the rake.

Remember all perimeter details must be closed so no air can get under the panels.



Expansion Cleats

To minimize movement of roofing panels, a combination of fixed cleats and expansion cleats are required. The top part of an expansion cleat can slide back and forth in the base allowing the metal to expand and contract.



Sliding cleats

Low slope (or low pitch) roofs generally use longer panels than a steep roof. The longer the panel — the more linear expansion can be expected. To reduce the effect this has on the ridge or eave the fixed cleats should be placed in the center with expansion cleats on either side. This will split the expansion at each end in half.



Installing a low pitch

Since a medium pitch roof will usually be shorter there is less material expansion to deal with. The fixed cleats can be placed closer to the ridge — approximately 2/3 of the way up.



Installing a medium pitch

On steep roofs the fixed cleats can be placed at the ridge with the expansion cleats towards the eave.

From Metal Roofing Magazine

Featured Local Company

Ideal Roofing & Gutters,LLC

920-923-2251
310 Tompkins St.
Fond du Lac, WI
www.idealroofingandgutters.com

Related Articles
- Bifold Doors Installation Oshkosh WI
Installing bi-fold closet doors is an easy DIY project. One of my projects that I need to do before the baby comes is to install the bi-fold closet doors in the baby's room. So today I did it and took a few pictures so I can show you how easy it really is.
- Before You Build That Top Oshkosh WI
- Roofing Watertightness Warranties Oshkosh WI
- Proper Vents Oshkosh WI
- Closet Components Installation Oshkosh WI
- Cabinet Clamps Oshkosh WI
- Total House Construction Series Oshkosh WI
- Undercabinet Lighting Oshkosh WI
- Installation of Stone Countertops Oshkosh WI
- Things To Consider In Shower Door Installation Oshkosh WI
Related Articles
- Bifold Doors Installation Oshkosh WI
Installing bi-fold closet doors is an easy DIY project. One of my projects that I need to do before the baby comes is to install the bi-fold closet doors in the baby's room. So today I did it and took a few pictures so I can show you how easy it really is.
- Before You Build That Top Oshkosh WI
- Roofing Watertightness Warranties Oshkosh WI
- Proper Vents Oshkosh WI
- Closet Components Installation Oshkosh WI
- Cabinet Clamps Oshkosh WI
- Total House Construction Series Oshkosh WI
- Undercabinet Lighting Oshkosh WI
- Installation of Stone Countertops Oshkosh WI
- Things To Consider In Shower Door Installation Oshkosh WI

Rss   Delicious   Digg   Add To My Yahoo   Add To My Google   Bookmark   Search Plugin

Topics:
Advertising Family Home Services Real Estate Resources
Business Services Fashion Industrial Goods & Services Retail & Consumer Services
Career Financial Services Insurance Software
Cars Food & Beverage Internet Technology
Computer Hardware Franchise Legal Telecommunications
Construction Health Miscellaneous Trade Shows
Education Holidays Nightlife Travel
Entertainment Home Appliances Online Database Weddings
Environmental Home Electronics Pets World History