On one recent project the architect and engineer wrangled about a suitable window-to-wall ratio. The result was a system with massive timber columns, interior and exterior plywood, full-height steel rods, and about every size hold-down in the universe. It was costly and complicated, and we were installing hardware for weeks.

Local Companies

CanSpec Inspection Services - Sault Ste Marie
1-877-672-3242
Sault Ste Marie, ON
Wolverine Fire Protection
(313) 964-5823
1229 Spruce St
Detroit, MI
Fricano Construction Inc
(616) 656-9430
4800 Broadmoor Ave SE
Grand Rapids, MI
Cunningham Limp Company
(248) 489-2300
39300 W 12 Mile Rd Ste 200
Farmington Hills, MI
Penniman Development Co
(734) 454-0707
1059 Penniman Ave
Plymouth, MI
Mechanical Engineering & Construction
(248) 351-9905
27130 Bradford Cir
Southfield, MI
Jessee Construction Inc
(810) 664-0662
600 S Wilder Rd
Lapeer, MI
MacArthur Construction
(989) 379-3288
Lachine, MI
Interior Space Management
(248) 362-4950
2081 Heide Dr
Troy, MI
Forcon International Michigan Limited Ltd
(231) 869-2017
7513 Harbor Dr
Pentwater, MI

 

Provided By:

Here in the Western mountains, we build homes with massive windows in every room to capture the 360-degree views. And as a framer, that's where the problem starts.

Architecture is a blend of art and science, two diametrically opposite disciplines. The artist wants the entire wall to be glass, like a giant landscape portrait; the scientist needs enough wall to hold the house up.

On one recent project the architect and engineer wrangled about a suitable window-to-wall ratio. The result was a system with massive timber columns, interior and exterior plywood, full-height steel rods, and about every size hold-down in the universe. It was costly and complicated, and we were installing hardware for weeks. So it was good news when we found Simpson Strong-Tie's newly code-approved (IBC, IRC, and UBC) Steel Strong-Wall shear wall, which will help resolve these complicated conflicts.

How It Works

The Steel Strong-Wall is designed to support vertical and lateral loads produced by wind or earthquakes, creating a strong but narrow shear wall. They're superior to, and can replace, Simpson HD and HDA hold-down assemblies and wood composition panels when attaching to a foundation.

The Steel Strong-Wall shear wall is a 10-gauge galvanized steel panel with a 2-by wood stud secured to either side and a steel plate top and bottom.

Click here to read full article from Tools of the Trade

Featured Local Company

CanSpec Inspection Services - Sault Ste Marie

1-877-672-3242
Sault Ste Marie, ON
http://www.casaguru.com/p/-/p/154005/CanSpec-Inspection-Services-Sault-Ste-Marie


Rss   Delicious   Digg   Add To My Yahoo   Add To My Google   Bookmark   Search Plugin

Topics:
Advertising Family Home Services Real Estate Resources
Business Services Fashion Industrial Goods & Services Retail & Consumer Services
Career Financial Services Insurance Software
Cars Food & Beverage Internet Technology
Computer Hardware Franchise Legal Telecommunications
Construction Health Miscellaneous Trade Shows
Education Holidays Nightlife Travel
Entertainment Home Appliances Online Database Weddings
Environmental Home Electronics Pets World History