Just as poor flashing details are much more likely to be the cause of a leak than the roofing itself, many leaks are caused by the use of insufficient or inadequate fasteners for sheathing, flashing, or roofing, and by the attempt to substitute caulk or roofing cement for flashing.

Local Companies

S&J Roofing
678-914-2166
6151 Old Stilesboro Rd
Acworth, GA
Willow Ash Roofing
770-516-0055
183 Laurel Way
Woodstock, GA
Brumlow Roofing & Restoration
678-954-8517
128 Lighthouse Drive
Dallas, GA
Commercial roof repair
678-859-7208
973 otter way
marietta, GA
GutterStuffPro of Georgia LLC
678-799-9766
822 Fox Hollow Pkwy
Marietta, GA
Armor Roofing Company
(770) 780-9111
2451 Cumberland Pkwy Se
Atlanta, GA
Tailored Home Stylists
(770) 516-8510
415 Ridgetop Dr NW
Acworth, GA
Kennesaw Maintenance & Repair Inc
(770) 975-7350
2679 Corinault Way NW
Acworth, GA
Southern Masterpiece Renovations Llc
(678) 445-5581
370 Hicks Farm Rd NW
Acworth, GA
Elie Construction Company
(770) 917-1200
3358 Forest Grove Ct NW
Acworth, GA

Provided By:

Source: REPLACEMENT CONTRACTOR Magazine
Publication date: November 1, 2005

By Harrison McCampbell

Just as poor flashing details are much more likely to be the cause of a leak than the roofing itself, many leaks are caused by the use of insufficient or inadequate fasteners for sheathing, flashing, or roofing, and by the attempt to substitute caulk or roofing cement for flashing.

The following fastener-related problems are among the most common. In every case, the leak could have been avoided had the installer used common sense and paid more attention to detail. —Adapted from “Troubleshooting Roof Leaks,” by Harrison McCampbell, which first appeared in the October 1999 issue of THE JOURNAL OF LIGHT CONSTRUCTION ( www.jlconline.com ), a sister publication of REPLACEMENT CONTRACTOR.

Problem: The plywood sheathing on this flat roof was installed without using blocking for support under the edges. If someone walks on the roof, the roofing may crack when the sheathing flexes at the plywood joints.

Solution: Use H-clips or solid blocking at plywood edges, or use tongue-and-groove plywood roof sheathing.

Problem: Smooth-shank common nails used to fasten roof sheathing don't hold and can work themselves loose, especially if a roof deck is walked on. Rising nail heads can eventually poke through the roofing.

Solution: Use ring-shank nails for roof sheathing.

Problem

Click here to read full article from Replacement Contractor

Featured Local Company

S&J Roofing

678-914-2166
6151 Old Stilesboro Rd
Acworth, GA


Rss   Delicious   Digg   Add To My Yahoo   Add To My Google   Bookmark   Search Plugin

Topics:
Advertising Family Home Services Real Estate Resources
Business Services Fashion Industrial Goods & Services Retail & Consumer Services
Career Financial Services Insurance Software
Cars Food & Beverage Internet Technology
Computer Hardware Franchise Legal Telecommunications
Construction Health Miscellaneous Trade Shows
Education Holidays Nightlife Travel
Entertainment Home Appliances Online Database Weddings
Environmental Home Electronics Pets World History